Before operating the probe, make sure there is no moisture in the detection area. Dry the detector with a cloth if necessary.
Press the start/stop button 5 to start the instrument:
After a short period of automatic testing, the probe is ready to run. The instrument automatically enters the function mode of metal detection. At this time, if there is a signal display in area 9 on the display screen without metal interference, it indicates that calibration is required. The calibration method is:Place the instrument in an environment free from metal and strong magnetic field interference (such as: Lifting the instrument into the air by hand, etc.), and then press and hold the detection metal button until the signal in area 9 of the display screen shows zero and the green light is on, and then the calibration is completed. At this time, release the button to detect the metal work.